12.1" color TFT screen Patient Monitor ME9000

Share
documents & resoures

12.1" color TFT screen Patient Monitor ME9000


12.1" color TFT screen 

Multi‐channel display 

Big font interface

ST and arrhythmia analysis

Drug dose calculation and titration table

OxyCRG dynamic view display

Respiration monitoring with apnea alarms


Alarm review, arrhythmia review 

Patient info. Input 

Anti‐defibrillation design

NIBP over pressure protection

Plug‐in rechargeable battery, AC/DC available. 

Supporting wire or wireless network.


Technical Specifications


ECG


Lead Mode                          5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) 

Lead selection                     I, II, III, avR, avL, avF, V

Wavef orm                          2 ch

Lead mode                          3 Leads ( R, L, F or RA, LA, LL) 

Lead selection                     I, II, III,

Wave form                          1 ch

Gain                               2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto


HR and Alarm Range                 Adult    15 ~ 300 bpm

                                   Neo/Ped    15 ~ 350 bpm

Accuracy                           ±1% or±1bpm, which is greater

Resolution                         1 bpm 

Sensitivity                        > 200 (uVp-p) 

Differential Input Impedance       > 5 MΩ


CMRR                                      Monitor > 105 dB 

                                                Operation > 105 dB 

                                                Diagnosis > 85 dB

Electrode offset potential         ±300mV 

Leakage Current                    < 10 uA

Baseline Recovery                  < 3 S After Defi. 

ECG Signal Range                   ±8 m V ( Vp-p ) 


Bandwidth                           Surgery    1 ~ 20 Hz

                                            Monitor     0.5 ~ 40 Hz

                                            Diagnostic  0.05 ~ 130 Hz

Calibration Signal                  1 (mVp-p),  Accuracy:5%

ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV


ARR Detecting                       Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,

                                          PNP, PNC,Alarm Available,Review Available


Respiration


Method                                        Impedance between R-F(RA-LL)

Differential Input Impedance       > 2.5 MΩ

Measuring Impedance Range          0.3~3 Ω

Base line Impedance Range           200~4 KΩ

Bandwidth                          0.1~2.5Hz

Resp. Rate                         Measuring and Alarm Range

                                    Adult 0 ~ 120 Brpm 

                                    Neo/Ped 0 ~ 150 Brpm 

                                    Resolution 1 Brpm 

                                    Accuracy ±2 Brpm


Apnea Alarm                        10 ~ 40 S


NIBP 


Method                            Oscillometric

Mode                              Manual, Auto, STAT                        

Measuring Interval in AUTO Mode   1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)

Measuring Period in STAT Mode     5 Min

Pulse Rate Range           40 ~ 240 bpm

Alarm Type                  SYS, DIA, MEAN


Measuring and alarm range        Adult Mode

                                    SYS 40 ~ 270 mmHg 

                                    DIA 10 ~ 215 mmHg 

                                    MEAN 20 ~ 235 mmHg

                                Pediatric Mode

                                    SYS 40 ~ 200 mmHg 

                                    DIA 10 ~ 150 mmHg 

                                    MEAN 20 ~ 165 mmHg

                                Neonatal Mode

                                    SYS 40 ~ 135 mmHg 

                                    DIA 10 ~ 100 mmHg 

                                    MEAN 20 ~ 110 mmHg

Resolution                      1mmHg


Accuracy                        Maximum Mean error ±5mmHg

                                       Maximum Standard deviation ±8mmHg

Overpressure Protection          Adult Mode 297±3 mmHg 

                                 Pediatric Mode 240±3 mmHg 

                                 Neonatal Mode 147±3 mmHg


SpO2

Measuring Range                  0 ~ 100 % 

Alarm Range                         0 ~ 100 % 

Resolution                            1 %

Accuracy                              70% ~ 100%  2 %

                                             0%  ~  69% unspecified

Actualization intervalabout      1 Sec. 

Alarm Delay                      10 Sec.

Pulse Rate                       Measuring and Alarm Range 20~300 bpm

                                         Resolution       1bpm

                                         Accuracy ±3bpm

                                   



TEMP


Channel                          2

Measuring and Alarm Range 0 ~ 50 ℃

Resolution                      0.1 ℃

Accuracy                        ±0.2 ℃

Actualization intervalabout     1 Sec.

Average Time Constant           < 10 Sec.


IBP


Label                           ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range       ART 0 ~ 300 mmHg 

                                PA -6 ~ 120 mmHg

                                CVP/RAP/LAP/ICP-10 ~ 40 mmHg

                                P1 / P2-10 ~ 300 mmHg 



Press Sensor                    Sensitivity 5  uV/V/mmHg

                                         Impedance 300-3000Ω


Resolution                      1 mmHg

Accuracy                        ±2% or 1mmHg which is greater

Actualization interval         about 1 secretary


Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature

Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder

12.1" color TFT screen Patient Monitor ME9000