The Environmental Of Installing Electric Dialysis Chair ME-YD-230


Features of Electric Dialysis Chair ME-YD-230


1. Water supply temperature
The 1kW heater can only heat 500ml/min water 28 ° C. For low -power heater, the water supply temperature and dialysis fluid flow should be considered. The dialysis machine only has heating and heating function, and cooling can only rely on naturally dissipating heat. Therefore, the temperature in the water is too high, and the machine cannot operate normally.

2. Atmospheric pressure
Pressure sensor: Pressure monitoring is an important monitoring method on the dialysis machine. The pressure on the dialysis machine is relatively stressful, which is the pressure of the current atmospheric pressure, not the pressure of the absolute vacuum.
The monitoring of the pressure on the dialysis machine is more inclined to change the trend of pressure changes, not the specific value.
The venous pressure zero is the most affected by the atmospheric pressure.
Boiling point:The liquid boils at different atmospheric pressures.In the process of hot cleaning and heat disinfection, the temperature must not reach the boiling point.Focus on installation settings in high altitude areas.

3.Water supply
Single water supply flow 500ml/min.
The water supply of most models is intermittent, so the water supply flow is greater than the actual dialysis liquid flow.
When some models are cleaned and disinfected, the actual traffic will be higher than the treatment flow (500ml/min).
Part of the treatment requirements in the treatment requirement using high dialysis liquid flow treatment is an example, which has little effect on the total water supply requirements.

Matters needing attention

Always check the power cord, etc.Pay special attention to the power supply and other wires should not be caught or crushed by casters or other heavy objects. In particular, the power line, once damaged, may occur burning, leakage, there is a risk of fire and electric shock.

1.Do not spill liquid on electrical parts
Do not spill water, juice, miso soup, etc. On the motor, sensor or handheld operator. Otherwise, the dialysis chair will not work or have a local failure. When accidentally spilled, the power plug must be unplugged from the socket and contact the dealer.

2.Do not damage the electric drive operator
Do not beat the hand-held electric drive operator or pull the spring wire.Otherwise, it will cause rupture and damage.
Maintenance work must be performed after unplugging the power plug.
The power plug must be removed from the socket during maintenance.Remove the power plug if you do not use it for a long time.When not in use for a long time, the power plug must be unplugged from the socket.Designed for one person only.
The dialysis chair is designed for 1 person and cannot be used by more than 2 people at the same time.
 
3.Do not place objects under the chair

Do not place objects under the chair. Also, do not place near walls. Obstacles can cause damage to the chair when doing back, foot, or height adjustment.
 
4.Avoid moving on uneven surfaces
Try to avoid moving on roads or corridors with large steps or sharp bumps in the road surface, otherwise, failure will occur. If you must move in the above places, move as slowly as possible.

Repair and maintenance

1. Regular inspection
To ensure safe use, regular inspections and maintenance must be performed.

2. Cleaning and disinfection of chairs
When cleaning, first wipe the neutrally detergent diluted with water, and then wipe it with a dry cloth. It is forbidden to wipe the use of volatile solvents (scarcity, volatile oil, gasoline, etc.). Otherwise, there is a danger of discoloration and deterioration. When using disinfectant, the following drugs must be diluted to the specified concentration before use. 0.05 ~ 0.2%chloroblaxane ammonium, 0.05 ~ 0.2%chloride cylindrite ammonium, 0.05 ~ 0.2%washing Bibita.

(Attention: This dialysis chair is not suitable for disinfection with ozone sterilizers and high -voltage steam.)

Multifunctional Medical Delicated Dialysis Chair (ME-YD-230)Multifunctional Medical Delicated Dialysis Chair (ME-YD-230)Multifunctional Medical Delicated Dialysis Chair (ME-YD-230)


 

Whats your MOQ ?Our MOQ is one psc, welcome to trial order before our formal cooperation.
If your company support OEM ?Yes, we support OEM, You just sent me our your logo and requirement, we will print th logo in the products and nameplate. 
What's our payment ways and methods? Our payment ways is T/T: 30% before producing, and 70% before shipping the products.L/C at sight and westunion.
Whats terms of the transaction ?Our general quotation is EXW, after confirm details quantity with customer, will quote CFR.We also support DDP.



Get in Touch
Contact Us

Copyright © Shanghai MedEco Industry Co., Ltd. All Rights Reserved | Sitemap| Powered by |

skype
whatsapp
E-mail